I performed heating maintenance on a Lennox Elite EL296 gas furnace in Denton, TX last evening, ensuring it was ready for winter. I started by inspecting the heat exchanger for cracks and cleaning the burners to ensure proper combustion. I replaced the air filter with a 20x25x1 high-efficiency filter and lubricated the blower motor. The flame sensor was polished, and the gas valve was calibrated for optimal operation. Finally, I tested the safety switches and thermostat for functionality. The system passed all diagnostic tests and was running efficiently, providing reliable heating for the customer.
In Aubrey, TX, I repaired a Trane XR95 gas furnace that was not igniting properly. I replaced a faulty igniter with an OEM part, cleaned the flame sensor, and inspected the burners for buildup. After testing, the system was operating efficiently and safely for reliable heating.
I completed a heat tune-up on a Carrier gas furnace for a customer in Krugerville. First, I inspected and cleaned the flame sensor and burners to maintain proper combustion. I then tested the blower motor for optimal airflow and ensured the gas pressure was within manufacturer specifications. I also verified the heat exchanger was free from cracks. Lastly, I adjusted the thermostat settings and tested the system’s overall operation to confirm proper heating performance throughout the home.
Repaired Lennox EL296V two-stage furnace with no heat complaint in Denton. Diagnosed failed pressure switch using digital manometer. Replaced switch with OEM part 103935-03. Cleaned flame sensor with fine-grit sandpaper. Verified inducer motor operation. Checked all limit switches. Adjusted blower speed for proper temperature rise. Cycled system through both stages to ensure proper operation. Restored heat to residence.
I completed an HVAC repair for a customer whose system was not functioning properly. Upon inspection, I found that the blower motor capacitor had failed, causing the blower to not start. I replaced the faulty capacitor with a new 35/5 MFD dual-run capacitor, then checked the motor for proper operation. Additionally, I inspected the evaporator coil and noticed dirt buildup, which was affecting airflow. After cleaning the coil and confirming the blower motor was running efficiently, I performed a full system diagnostic. The HVAC system is now working properly, providing consistent airflow and improved cooling performance.
I completed a ductwork repair for a customer who was experiencing reduced airflow in their home. After inspecting the duct system, I found several leaks and gaps in the duct joints, which were causing significant air loss. I sealed the leaks using mastic sealant and reinforced the connections with aluminum tape for added durability. I also wrapped sections of the ductwork with R-8 insulation to improve energy efficiency and reduce future air loss. After the repairs, I performed a pressure test to confirm that the system was now sealed. The home’s airflow is restored, and the HVAC system is running more efficiently.
I inspected an HVAC system that wasn’t cooling properly. The issue was traced to a low refrigerant charge, likely caused by a small leak. I recharged the system with refrigerant and used a UV dye to identify the source of the leak. The unit is now cooling effectively, and I will follow up to address the leak if needed.
I diagnosed and repaired a faulty Copeland scroll compressor in a Carrier 24ABC6 central air conditioner. After testing the capacitor and contactor, I found a refrigerant leak in the evaporator coil. I sealed the leak using Rectorseal AC Leak Freeze, recharged the system with R-410A refrigerant, and replaced the filter drier. The unit now operates at peak efficiency.
I addressed a Rheem RGGE-07EAUER gas furnace that wasn't producing heat. Upon inspection, I found a defective hot surface ignitor and a dirty flame sensor. I replaced the ignitor with a universal Silicon Nitride 120V model and cleaned the flame sensor using fine-grit sandpaper. I also replaced the air filter with a new MERV 11 pleated filter. After reassembly, I tested the furnace through multiple heating cycles to ensure proper ignition and heat production.
Completed a thorough air duct cleaning for a home with a Trane XR16 AC unit. Used a high-powered Rotobrush system to remove dust, debris, and allergens from the ductwork. Cleaned the blower motor, evaporator coil, and air handler to ensure optimal airflow and efficiency. Sealed any gaps and leaks in the ductwork to prevent future contamination. Regular air duct cleaning is essential for maintaining indoor air quality and HVAC performance. For professional air duct cleaning services, contact us today.
Completed an AC repair in Denton, TX, on a Lennox XC21 unit. Diagnosed a malfunctioning condenser fan motor and replaced it with a Lennox OEM part to restore proper airflow. Checked refrigerant levels and recharged with R-410A for optimal cooling efficiency. Inspected and cleaned the evaporator and condenser coils to ensure maximum performance. Regular maintenance and timely repairs are crucial for system longevity. For expert AC repair services, contact us for professional and reliable solutions in Denton, TX.
Completed AC repair involving a non-cooling unit. Diagnosed and fixed a refrigerant leak, recharged the system, and replaced a malfunctioning capacitor. Cleaned the condenser coils and replaced the clogged air filter. Ensured all electrical connections were secure and tested the system for proper cooling and efficient operation. The AC unit is now functioning optimally, providing reliable cooling performance.
I performed an HVAC repair on a Trane system. The unit had a malfunctioning capacitor, which I replaced with a new OEM part. I also checked the refrigerant levels and topped off with R-410A as needed. After inspecting the blower motor and cleaning the coils, I tested the system to ensure it was operating efficiently.
Installed a Rheem RP1448AJ1NA two-zone central air conditioning system in a residential home. Mounted the 4-ton outdoor condensing unit on a concrete pad using Rubber-A-Mounts for vibration isolation. Ran two separate sets of refrigerant lineset piping to indoor evaporator coils located in the attic space - one for the living room and one for the master bedroom. Used existing ductwork and installed motorized zone dampers to control airflow to each zone. Evacuated the entire system to 500 microns using a Fieldpiece EVAC4WAY vacuum pump. Charged with 3 lbs 8 oz of R-410A refrigerant per Rheem's specifications. Programmed the Rheem AccuLink zoning control board and verified proper cooling operation in each zone.
This morning, I conducted the yearly preventative maintenance on a Rheem Classic Series central air conditioning system at a local home. I started by thoroughly cleaning the condenser coils on the outdoor unit using a non-acidic coil cleaner and a soft-bristle brush. Next, I replaced the MERV 8 air filter in the air handler and inspected all electrical components, ensuring proper voltage and amperage. I also checked the refrigerant charge and performed a leak test, finding no issues. The system is now operating at peak efficiency and performance.
This afternoon, I investigated a noise issue with a Carrier central air conditioning system at a home in Denton, Texas. The homeowner reported an unusual rattling sound coming from the outdoor condenser unit. Upon inspection, I found that one of the condenser fan blades had become loose, causing it to vibrate against the fan housing. I carefully tightened the blade attachment and rebalanced the fan assembly. I also performed a general cleaning of the condenser coils and checked all electrical connections. The system is now operating quietly and efficiently, meeting the homeowner's expectations.
Today in Denton, TX, I repaired residential air ducts using Aeroseal to seal leaks and improve efficiency. I first conducted a pressure test to identify the leaks, then applied the sealant through the duct system to ensure airtight sealing. The final airflow measurement confirmed significantly enhanced circulation throughout the home.
I conducted a routine maintenance check on the HVAC system and found no issues. This maintenance included inspecting the thermostat for accuracy, cleaning the air filters to ensure unobstructed airflow, checking refrigerant levels for optimal performance, and lubricating moving parts to reduce wear. The electrical connections were also examined and tightened to guarantee safe operation.
Performed comprehensive maintenance and safety inspection on a Lennox SLP98V furnace in Aubrey, TX. Inspected electrical components, replaced filters, and ensured proper ventilation. Verified safe operation and efficiency for optimal heating performance, prioritizing the comfort and safety of the homeowner's environment.
Installed a Bryant Evolution Series air purifier integrated into the HVAC system for a customer in Pilot Point, TX, who suffers from asthma. The purifier's advanced filtration technology captures allergens, dust, and pollutants, ensuring cleaner indoor air. This significantly reduces asthma triggers, promoting healthier breathing and comfort for the homeowner.
Installed new flexible ductwork in Denton, TX. Crafted with premium materials, the ducting optimizes airflow and reduces energy waste. Its pliability facilitates simple installation in confined areas, while the insulated construction sustains uniform temperatures, heightening comfort and energy efficiency for Denton homeowners.
Furnace Repair - Ignition Problems. Client has a gas furnace, ignition system needed to be replaced because it was not working altogether. Older furnace with multiple repairs over the past 2 years. Client considering Furnace replacement in Celina home.
Responded to a heat pump repair call for a valued client on a Goodman 2.5-ton unit. Diagnosed the issue to find a malfunction in the compressor. Conducted comprehensive tests to verify the repair's success and optimize the unit's performance. The Goodman heat pump is now restored to its best condition, providing reliable heating and cooling.
Completed the installation of a Rheem HVAC system, replacing a 20-year-old Rheem unit. The upgrade involved removal of the outdated system, positioning and securing the new Trane components, and connecting ductwork for seamless integration. Completed thorough system tests to ensure efficient heating and cooling. The advanced features of the new system promise improved energy efficiency and reliable performance, ensuring enhanced comfort for years to come.
Heating is not working at all. Client reports that the heat has not worked on the second floor since cooler weather has arrived. System is a dual system heat pump. System serving upstairs required repair so the other heat pump was not working twice as hard with heat escaping to the second story. Repair completed.