Why CVJ Heating & Cooling Is the Most Trustworthy HVAC Service in Denton, TX
When it is hot, it is HOT and when it is cold, it is COLD here in North Texas. Hot or cold, you need to make sure your home's air conditioning and heating system can keep your home just the right temperature. But do you know that your system is in good shape? Are you certain it won't give out right when you need it most? Even if the answers are no, don't worry - because CVJ Heating & Air Conditioning is here to help. We will inspect your system, repair what can be fixed, and replace what can't, all so you're ready to go no matter the season in Denton, TX.
Don’t wait until the heatwave hits—schedule your AC service today! Call us now at 940-251-2941 or message us online if you prefer to schedule your service!
Expert AC Services in Denton, TX
Is your home prepared for the scorching North Texas summer ahead? Don't let rising temperatures leave you sweating in discomfort when professional cooling solutions are just a call away.
Professional AC Services from Denton's Most Trusted HVAC Team
Our certified technicians bring years of specialized experience to every air conditioning project, ensuring your home stays cool and comfortable even during triple-digit temperature days. From minor repairs to complete system installations, our comprehensive expertise guarantees reliable solutions tailored to your specific needs.
Our services near Denton, TX include:
AC Repair
Is your air conditioner struggling to keep up with rising temperatures or making strange noises? Our skilled team will diagnose the issue and restore your cooling system efficiently.
AC Replacement
All good things come to an end - even our AC units. When yours is at the end of its lifespan, we can help you find a high-tech, energy-efficient replacement perfect for your home.
AC Maintenance
Looking to nip significant issues in the bud? Our regular maintenance plans ensure your AC gets the TLC it needs to keep running for a long time.
Don't wait until it's too late. Get your system checked out today. 940-251-2941 We are ready to serve your needs!
Denton Furnace Repair & Heating Service When You Need It
When the temperature drops, a reliable heating system is essential. Don’t let a failing furnace leave you in the cold—our team is ready to help with fast and efficient heating services.
Our services include:
Heating & Furnace Repair
Is your furnace or heating pump is struggling to heat your home or making strange noises (and smells too)? We can perform the right repairs to make your home heating work again.
Heat Pump or Furnace Replacement
When your heating systems don't work, throwing more money at repairs - when they land you with another heating breakdown is pointless. Trust the professional heating contractors at CVJ to assist you with just the right timing!
Heating & HVAC Maintenance
Looking to nip significant issues in the bud? Our regular maintenance plans ensure your AC gets the TLC it needs to keep running for a long time.
For a heating company that cares near Denton, call your friends at CVJ Heating & Cooling.
Denton, TX HVAC FAQs
The time required to repair an air conditioner in Denton, TX, depends on the issue’s complexity, system type, and part availability. In most cases, repairs can be completed within a few hours, but more extensive fixes may take longer.
Common AC Repair Timelines:
- Minor Repairs (1–2 hours): Thermostat adjustments, capacitor replacements, or refrigerant recharges.
- Moderate Repairs (2–4 hours): Fixing refrigerant leaks, replacing fan motors, or cleaning evaporator coils.
- Major Repairs (4+ hours to a day): Compressor replacement, extensive electrical issues, or multiple system component failures.
Regular AC maintenance can prevent unexpected breakdowns and shorten repair times. If your AC isn’t working properly, contact a Denton HVAC professional to diagnose and fix the issue promptly.
HVAC installation in Denton, TX, involves a detailed process tailored to the region's climate. Here's a breakdown:
- System Assessment:
- Professionals begin by evaluating your home's size, layout, and insulation to determine the appropriate HVAC system.
- This includes calculating the necessary heating and cooling load.
- Professionals begin by evaluating your home's size, layout, and insulation to determine the appropriate HVAC system.
- Equipment Installation:
- This involves installing the indoor unit (furnace or air handler) and the outdoor unit (condenser).
- Ductwork installation or modification is often necessary to ensure proper airflow.
- Thermostat installation is also a key part of the installation.
- This involves installing the indoor unit (furnace or air handler) and the outdoor unit (condenser).
- Connections and Testing:
- Technicians connect electrical wiring, refrigerant lines, and gas lines (if applicable).
- They then test the system to ensure it operates efficiently and safely.
- Final Checks:
- This includes verifying proper airflow, checking for leaks, and ensuring the thermostat functions correctly.
- Professionals will also often give the home owner instruction on the new systems operation.
Because of the Texas heat, proper Air conditioning installation is very important.
Several factors can cause a furnace to blow cold air in Denton, TX, where winter temperatures can still dip. Here's a breakdown of common culprits:
- Thermostat Issues:
- A misconfigured or malfunctioning thermostat can send incorrect signals to the furnace.
- If the fan is set to "on" instead of "auto," the fan may blow air even when the furnace isn't heating.
- A misconfigured or malfunctioning thermostat can send incorrect signals to the furnace.
- Ignition Problems:
- If the furnace's igniter or pilot light fails, the burners won't ignite, resulting in cold airflow.
- This can be due to a faulty gas valve or a dirty flame sensor.
- If the furnace's igniter or pilot light fails, the burners won't ignite, resulting in cold airflow.
- Airflow Restrictions:
- A dirty air filter can restrict airflow, causing the furnace to overheat and shut down.
- This can lead to the fan blowing cold air after the furnace's safety switch is activated.
- limit switch problems are also common.
- A dirty air filter can restrict airflow, causing the furnace to overheat and shut down.
- Gas Supply Issues:
- Problems with the gas supply, such as a tripped gas valve or low gas pressure, can prevent the furnace from heating.
- Problems with the gas supply, such as a tripped gas valve or low gas pressure, can prevent the furnace from heating.
- Overheating:
- Although counter intuitive, if a furnace is over heating, it will shut off the heating element, and then the fan will continue to run, blowing cold air.
Addressing these issues promptly is crucial for maintaining optimal energy efficiency and preventing costly repairs.
Installing a heat pump in Denton, TX, offers several advantages, particularly given the region's climate. Here's a breakdown:
- Year-Round Comfort:
- Heat pumps provide both heating and cooling, eliminating the need for separate systems.
- This offers consistent comfort throughout Denton's varying seasons.
- Heat pumps provide both heating and cooling, eliminating the need for separate systems.
- Energy Efficiency:
- Heat pumps transfer heat rather than generating it, making them significantly more energy-efficient than traditional furnaces.
- This translates to lower utility bills, a significant benefit in Texas summers and winters.
- Heat pumps transfer heat rather than generating it, making them significantly more energy-efficient than traditional furnaces.
- Cost Savings:
- While the initial installation cost may be higher, the long-term energy savings can offset the expense.
- Fewer repairs, due to having one unit instead of two, can also save money.
- Environmental Benefits:
- Heat pumps use electricity, which can be generated from renewable sources, reducing reliance on fossil fuels.
- This contributes to a smaller carbon footprint.
- Heat pumps use electricity, which can be generated from renewable sources, reducing reliance on fossil fuels.
- Improved Air Quality:
- Many modern heat pumps include advanced air filtration systems, which can improve indoor air quality.
- Many modern heat pumps include advanced air filtration systems, which can improve indoor air quality.
Because of the wide range of temperatures experienced in Denton, TX, heat pumps provide a versatile and cost effective solution
Exceptional Service with a Personal Touch: Denton's Premier HVAC Partner Since 1993
Since establishing our roots in 1993, CVJ Heating & Cooling has served thousands of North Texas homeowners with an unwavering commitment to quality workmanship and personalized attention. Our longevity in the competitive Denton HVAC market speaks volumes about our reliability and expertise. Read our reviews below and see why your neighbors trust CVJ!
Need fast, reliable HVAC service? Call us now at 940-251-2941 or contact us online!
Recent Jobs and Reviews in Denton, TX
Our Local Reviews by City
- Aubrey, TX (24)
- Denton, TX (10)
- Krugerville, TX (5)
- Little Elm, TX (4)
- Pilot Point, TX (11)
- Prosper, TX (1)
- Providence Village, TX (1)
- Sanger, TX (4)
Job Locations and Reviews
Investigated a no-cool call for a split system. Found low refrigerant pressure. Leak detection procedures identified a pinhole leak in the evaporator coil. Discussing repair versus replacement options based on system age and refrigerant type (R-410A).
Finished a residential HVAC system experiencing intermittent blower motor failure. Diagnosis indicated a failing capacitor. Replacement with a like-for-like 5uF capacitor restored proper airflow. System amperage draw now within manufacturer specifications. Regular system checks can identify such issues proactively.
I arrived at a home in Brookside for a thermostat repair job. Customer complained that their thermostat was not working. The homeowner reported the heating system wasn’t responding. After testing the thermostat, I discovered the real issue was a faulty furnace ignitor. I replaced the ignitor, tested the system, and restored proper heating. The customer was relieved to have quick, accurate service.
Arrived at a home in Oakwood for an air duct repair job. The homeowner complained of high energy bills and poor airflow. I located and sealed leaks, replaced damaged duct sections, and cleared debris. After testing, airflow improved significantly. The customer noticed better HVAC performance. Contact us for expert air duct repair services!
I arrived in Southridge for an air duct repair job. The homeowner reported weak airflow and uneven cooling. I sealed leaks, reinforced connections, replaced damaged ducts, and removed debris. After testing airflow, the system ran efficiently. The customer noticed immediate improvements. Contact us for expert air duct repair services!
Performed annual maintenance on a Bryant Evolution furnace. Cleaned the burner assembly, inspected the heat exchanger for cracks, and tested the flame sensor. Checked and tightened all electrical connections and measured static pressure in the ductwork.
Repaired a Daikin DZ18TC heat pump that was tripping the breaker. The compressor's start capacitor had failed. Installed a new dual-run capacitor and checked the compressor amperage using a clamp meter. Verified that the unit operated without further trips.
Serviced a malfunctioning electric heater that wasn’t cycling properly. Found a defective limit switch using a continuity tester. Replaced the switch and inspected the heating elements for wear. Tested the heater to confirm proper cycling and heating performance.
Troubleshot a malfunctioning auxiliary heat system on a Rheem RP17 heat pump. The issue was due to a burned-out heat strip relay. Replaced the relay and tested the system in emergency heat mode, confirming proper auxiliary heat operation.
Performed routine maintenance on a Trane XR15 heat pump. Cleaned the condenser coils using a coil cleaner, checked the electrical connections, and tested the capacitor. Verified proper airflow and ensured the refrigerant charge was within acceptable limits.
I repaired a Lennox XP16 heat pump that was not blowing warm air. After inspecting the system, I found a faulty reversing valve. Replaced the valve and recharged the refrigerant to the correct level using an R-410A manifold gauge set.
I performed HVAC repair on a York system in Denton. The issue was a faulty capacitor that caused the AC to stop running. I replaced the capacitor, cleaned the condenser coils, and checked the refrigerant levels. The system is now operating smoothly and cooling effectively.
Today, I completed heating maintenance on a Carrier furnace in Denton. I inspected the heat exchanger, cleaned the burners, and replaced the air filter. I also tested the gas pressure and verified the thermostat calibration. The furnace is now ready for the colder months ahead.
I performed heating maintenance on a Lennox Elite EL296 gas furnace in Denton, TX last evening, ensuring it was ready for winter. I started by inspecting the heat exchanger for cracks and cleaning the burners to ensure proper combustion. I replaced the air filter with a 20x25x1 high-efficiency filter and lubricated the blower motor. The flame sensor was polished, and the gas valve was calibrated for optimal operation. Finally, I tested the safety switches and thermostat for functionality. The system passed all diagnostic tests and was running efficiently, providing reliable heating for the customer.
In Denton, TX, I completed routine maintenance on a Carrier Infinity 96 gas furnace. I inspected the heat exchanger for cracks, cleaned the burners, replaced the 16x25x1 air filter, and calibrated the thermostat for accurate temperature readings. The safety controls were tested, and the system was confirmed to be ready for the colder months ahead.
Repaired Lennox EL296V two-stage furnace with no heat complaint in Denton. Diagnosed failed pressure switch using digital manometer. Replaced switch with OEM part 103935-03. Cleaned flame sensor with fine-grit sandpaper. Verified inducer motor operation. Checked all limit switches. Adjusted blower speed for proper temperature rise. Cycled system through both stages to ensure proper operation. Restored heat to residence.
Performed fall maintenance on Daikin FIT heat pump system with gas furnace backup in Denton. Cleaned outdoor coil using coil cleaner and low-pressure rinse. Checked refrigerant charge, topped off R-410A. Cleaned condensate drain line with compressed air. Replaced air filter with MERV 11 pleated filter. Inspected ductwork and sealed accessible leaks with mastic. Cleaned flame sensor and checked ignition sequence on furnace. Calibrated Daikin One+ thermostat. Installed Daikin premium air purifier. Conducted static pressure test and adjusted blower speed for optimal airflow. Left system in peak condition for heating season.
I responded to a service call for an HVAC system that wasn’t cooling. After inspecting the unit, I found the condenser fan motor had failed, preventing heat from dissipating. I replaced the faulty motor with a new OEM condenser fan motor and checked refrigerant levels, which were within range. After cleaning the condenser coil, I tested the system, and it is now cooling the home efficiently.
I repaired a Goodman GSX140361 3-ton air conditioner that was short cycling. After diagnosing the issue, I discovered a faulty run capacitor and a clogged condensate drain line. I replaced the 45/5 MFD dual run capacitor with a new USA-made Titan Pro capacitor. Then, I cleared the condensate line using a Guardair pneumatic drain gun. Finally, I cleaned the evaporator coil with Nu-Calgon Evap Foam cleaner to improve efficiency. The unit now runs smoothly without interruption.
I addressed a Rheem RGGE-07EAUER gas furnace that wasn't producing heat. Upon inspection, I found a defective hot surface ignitor and a dirty flame sensor. I replaced the ignitor with a universal Silicon Nitride 120V model and cleaned the flame sensor using fine-grit sandpaper. I also replaced the air filter with a new MERV 11 pleated filter. After reassembly, I tested the furnace through multiple heating cycles to ensure proper ignition and heat production.
Completed an AC repair in Denton, TX, on a Lennox XC21 unit. Diagnosed a malfunctioning condenser fan motor and replaced it with a Lennox OEM part to restore proper airflow. Checked refrigerant levels and recharged with R-410A for optimal cooling efficiency. Inspected and cleaned the evaporator and condenser coils to ensure maximum performance. Regular maintenance and timely repairs are crucial for system longevity. For expert AC repair services, contact us for professional and reliable solutions in Denton, TX.
Installed a new Rheem RP1448AJ1NA 4-ton air conditioning system with Copeland Scroll two-stage compressor. Replaced existing air handler with Rheem RGRM upflow gas furnace utilizing EcoNet control board. Ran new 3/8" liquid and 7/8" suction refrigerant lineset using Diversitech LineSet Cover insulation. Fabricated return air plenum using SMACNA guidelines with Stamford Shortbody elbows. Triple evacuated to 500 microns using a Yellow Jacket SuperEvac vacuum pump. Charged with 10 lbs of R-410A refrigerant per specifications on data plate. Installed Rheem EcoNet WiFi thermostat with dehumidification control and enabled two-stage cooling/heating operations.
I performed annual HVAC maintenance on a Carrier system. Tasks included cleaning the condenser and evaporator coils, checking and adjusting refrigerant levels, and inspecting the blower motor. I also tested the capacitor and contactor, calibrated the thermostat, and lubricated all moving parts. The system was thoroughly tested to ensure optimal performance and efficiency for the upcoming season.
Installed a Rheem RP1448AJ1NA two-zone central air conditioning system in a residential home. Mounted the 4-ton outdoor condensing unit on a concrete pad using Rubber-A-Mounts for vibration isolation. Ran two separate sets of refrigerant lineset piping to indoor evaporator coils located in the attic space - one for the living room and one for the master bedroom. Used existing ductwork and installed motorized zone dampers to control airflow to each zone. Evacuated the entire system to 500 microns using a Fieldpiece EVAC4WAY vacuum pump. Charged with 3 lbs 8 oz of R-410A refrigerant per Rheem's specifications. Programmed the Rheem AccuLink zoning control board and verified proper cooling operation in each zone.
This afternoon, I investigated a noise issue with a Carrier central air conditioning system at a home in Denton, Texas. The homeowner reported an unusual rattling sound coming from the outdoor condenser unit. Upon inspection, I found that one of the condenser fan blades had become loose, causing it to vibrate against the fan housing. I carefully tightened the blade attachment and rebalanced the fan assembly. I also performed a general cleaning of the condenser coils and checked all electrical connections. The system is now operating quietly and efficiently, meeting the homeowner's expectations.
Once again, the team at CVJ provided us with quality service and professional execution by the technicians, restoring our peace of mind.
Thank you Rhonda for allowing us to take care of your heating and cooling needs for all these years!
The tech was knowledgeable and friendly.
We appreciate you sharing your 5-star review with us and the community!
Efficient and courteous.
Thank you so much for your 5-star review! We will share this with the team to let them know to keep up the amazing work.
CVJ has always provided great customer service. They are knowledgeable and always friendly. The only A/C company I call.
Thank you so much for taking the time to leave us a 5-star review!
Angie quickly got back with me to get someone out to look at my system. When I told her I have no heat Steven was able to come out that day. I needed a new system and pricing was fair. The entire staff was professional and friendly from the phone call to installation and clean up. Highly recommended!!
We’re so happy you loved your experience and can’t wait to have you back for your next service appointment.
Great service. Polite.
Thank you so much for your 5-star review! We will share this with the team to let them know to keep up the amazing work.
I refer CVJ to everyone.
We are so grateful for your 5-star review. Thanks for sharing your rating with us and the community.
Ac
Thank you so much for this 5-star review.
I'm happy that I have been used them for years. Needless to say I will call them again.
We are so grateful for your 5-star review. Thanks for sharing your rating with us and the community.
A great Company 👍
We’re so happy you loved your experience and can’t wait to have you back for your next service appointment.